热门关键词:苏玛罐,技术支持,环境监测产品,液相色谱,色谱柱。
更新时间:2019-11-14
Dionex CarboPac SA10碳水化合物色谱柱这些离子交换柱提供单的快速,高效分离和双糖不影响分辨率。
免费咨询:010-61755520
对于生物燃料和食品样品中单糖的快速色谱分析,使用的Thermo Scientific戴安CARBOPACSA10分析及保护柱。这些离子交换柱提供单的快速,高效分离和双糖不影响分辨率。在只有10分钟或不到10分钟的8种常见的生物燃料的单糖和双糖分析食品中的六种常见的糖。
Dionex CarboPac SA10碳水化合物色谱柱
订货信息:
Dionex CarboPac SA10 碳水化合物分析柱
分析柱 | |
CarboPac SA10 Analytical Column (4 x 250mm) | 074641 |
Dionex CarboPac SA10 Analytical Column (2 x 250 mm) | 082322 |
保护柱 | |
CarboPac SA10 Guard Column (4 x 50mm) | 074902 |
Dionex CarboPac SA10 Guard Column (2 x 50 mm) | 082323 |
CarboPac SA10 Column for Fast, High-Resolution Mono- and Disaccharide Analysis
The Thermo Scientific Dionex CarboPac SA10 column line has been expanded to include a new 2 × 250 mm microbore column. This microbore column complements the already available standard-bore Dionex CarboPac SA10 (4 × 250 mm) Column. The new 2 mm format is optimally suitable for interfacing with Mass Spectrometric Detectors, as well as Pulsed Amperometric Detectors.
The Dionex CarboPac SA10 anion-exchange column is designed for fast chromatographic analysis of simple sugars in biofuel and food samples. The fast, efficient separations of mono- and disaccharides are achieved without compromising resolution. The Dionex CarboPac SA10 column can analyze six common sugars in food samples in only 10 min, or eight common biofuel mono- and disaccharides in less than 10 min.
Fast analysis
High resolution
High capacity
High reproducibility
No derivatization required
The Dionex CarboPac SA10 column is composed of a unique macroporous substrate coated with a strong anion-exchange layer of latex nano beads which provides high capacity and rapid high-resolution separations. The excellent resolution and linearity of this column provides highly accurate, quantitative carbohydrate analysis. Used in conjunction with pulsed amperometric detection (PAD) systems, the Dionex CarboPac SA10 column provides direct quantification of nonderivatized carbohydrates with minimal sample preparation or cleanup, and is capable of separating a wide range of sample concentrations. This column features high reproducibility, and can withstand thousands of injection cycles under high pH conditions.
CarboPac SA10 Column for Monosaccharide and Disaccharide Analysis Specifications | |
---|---|
Dimensions | CarboPac SA10 Analytical Column: 4 × 250 mm and 2 × 250 mm CarboPac SA10 Guard Column: 4 × 50 mm and 2 × 50 mm |
Maximum operating pressure | 3500 psi (24.5 MPa) |
Temperature range | 4–60 °C |
Typical operating conditions | 1700 psi at 1.5 mL/min (standard-bore column) or 0.38 mL/min (microbore column) Recommended flow rate: 1.5 mL/min (standard-bore) or 0.38 mL/min (microbore) |
Typical Eluents | Potassium hydroxide or sodium hydroxide |
Resin composition | 6-μm diameter substrate (ethylvinylbenzene 55% crosslinked with divinylbenzene) agglomerated with 55-nm MicroBead difunctional quaternary ammonium ion (4.5% cross-linked). |
Anion-exchange capacity | Approximately 290 μeq/column (4 × 250 mm standard-bore column) Approximately 73 μeq/column (2 × 250 mm microbore column) |
Column construction | PEEK |